| Measured values |
Br2, CCl4, C2Cl4, CCl2F2, C3F6, CH4, C2H2, C2H4, C2H6, C3H4, C3H6, C3H8, C4H6, C4H8, C4H10, C6H6, C6H14, C7H8, CH3Cl, CH2Cl2, CHCl3, C2H3Cl, C2H2Cl2, C2H4Cl2, C2HCl3, C6H5Cl, C6H4Cl2, CHCl2F, CH3OH, C3H7OH, C2H4(OH)2, CH3CHO, HCOOH, CH3COOC2H3, C2H2O, Cl2, CO, CO2, COCl2, HCl, HCN, HF, H2O, NH3, NO, N2O, NO2, R-NCO, SO2, SiF4, many other IR / VIS active gases and liquids |
| Measurement principles |
Interference filter correlation, Gas filter correlation |
| Spectral range |
|
| VIS version |
300 nm … 1,200 nm |
| IR-version |
1,200 nm … 12,000 nm |
|
| Measuring ranges |
More than 60 measuring components available (depending on concentration and sample gas composition)
Up to 6 components simultanously
2 measuring ranges per component
Automatic measuring range switching (adjaustable)
2 limit values per component
Measuring ranges depend on application and combination of measuring components |
| Response time (t90) |
|
|
30 s … 120 s
Adjustable |
|
| Zero point drift |
|
| VIS version |
< 1 %: of smallest measuring range per day |
| IR-version |
< 2 %: of smallest measuring range per week |
|
| Detection limit |
|
|
< 2 %: relative to measuring range end value |
|
| Ambient temperature |
|
|
+5 °C … +40 °C
Temperature change maximum ±10 °C/h |
|
| Storage temperature |
|
|
–20 °C … +60 °C |
|
| Ambient humidity |
|
|
≤ 80 %
Non-condensing |
|
| Ex-approvals |
|
| ATEX |
II 2G Ex px IIC T4 Gb
II 2G Ex px IIC T3 Gb
II 3G Ex pz IIC T4 Gc
Process cuvette: II 2G Ex e IIC Gb
II 3G Ex pz IIC T3 Gc |
|
| Electrical safety |
CE |
| Enclosure rating |
|
|
IP65: measuring cuvette depending on version |
|
| Analog outputs |
2 outputs:
0/4 … 22 mA, 500 Ω
Electrically isolated, max. number of outputs depends on application |
| Analog inputs |
2 inputs:
0/4 … 22 mA, 100 Ω
Electrically isolated, max. number of inputs depends on application |
| Digital outputs |
5 outputs:
2 power relays, electrically isolated, 3 outputs, potential-free, max. number of outputs depends on application |
| Digital inputs |
4 inputs:
Open contacts, potential-free, max. number of inputs depends on application |
| Modbus |
✔ |
| Remark |
Not in the Ex-version |
| Type of fieldbus integration |
TCP |
|
| Ethernet |
✔ |
| Remark |
Not in the Ex-version |
| Function |
Connection to SOPAS ET software or OPC server |
|
| Indication |
|
|
Status LEDs: “Power”, “Maintenance” and “Failure” |
|
LC display |
|
| Input |
Functional keys |
| Operation |
Via LC-display
Via software SOPAS ET (not in the Ex-version) |
| Dimensions (W x H x D) |
|
|
See dimensional drawings |
|
| Weight |
|
|
≤ 30 kg
Without measuring cuvette |
|
| Material in contact with media |
Measuring cuvette depending on version |
| Material |
Aluminium, coated |
| Power supply |
|
| Voltage |
Standard version: 115 V / 230 V
Ex-version: 230 V
Ex control device: 230 V |
| Frequency |
Analyzer: 50 … 60 Hz
Ex control device: 48 … 62 Hz |
| Power consumption |
Analyzer: ≤ 230 W
With cuvette heating: ≤ 805 W
With 2nd heating: ≤ 1,450 W |
|
|
|
| Corrective functions |
Cross-sensitivity compensation of up to 6 interferents |