Measured values | CO, CO2, H2O, N2O | ||||||||||||
Performance-tested measurands | CO, CO2, H2O | ||||||||||||
Measurement principles | Gas filter correlation, Interference filter correlation | ||||||||||||
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
Conformities | Approved for plants requiring approval
2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27.BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 MCERTS |
||||||||||||
Electrical safety | CE | ||||||||||||
|
|||||||||||||
Operation | Menu-driven operation via separate control unit | ||||||||||||
Model | Cross-duct version
Measuring probe version |
||||||||||||
Test functions | Automatic check cycle for zero and span point |
Description | Analyzer unit of the measuring system | ||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
Description | Measuring probe in open design with integrated purge air control system | ||||
|
|||||
|
|||||
|
|||||
|
|||||
|
|||||
|
|||||
Material in contact with media | Stainless steel 1.4571, stainless steel 1.4539 | ||||
|
|||||
Integrated components | Pressure sensor
PT1000 temperature sensor |
Description | Measuring probe with gas permeable filter element for adjustment with test gas | ||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|||||||||
Material in contact with media | Stainless steel 1.4571, stainless steel 1.4539, ceramics, PTFE | ||||||||
|
|||||||||
|
|||||||||
Integrated components | Pressure sensor
PT1000 temperature sensor |
Description | Reflector unit with hollow triple reflector | ||||
|
|||||
|
|||||
|
|||||
|
Description | The evaluation unit serves as the user interface and is responsible for data processing and output as well as control and monitoring functions. | ||||||||
|
|||||||||
Analog outputs | 3 outputs: 0/4 … 20 mA, 500 Ω Electrically isolated |
||||||||
Analog inputs | 1 input: 0 … 20 mA, 100 Ω |
||||||||
Digital outputs | 3 relay contacts: + 48 V AC, 1 A, 60 W / 48 V DC, 1 A, 30 W Preset for failure, maintenance and functional control |
||||||||
Digital inputs | 3 inputs: + 24 V |
||||||||
|
|||||||||
|
|||||||||
|
|||||||||
Input | Arrow keys
Functional keys |
||||||||
Operation | Menu-driven operation via LC-display and membrane keyboard | ||||||||
Model | Steel sheet enclosure | ||||||||
|
|||||||||
|
|||||||||
|
Description | The evaluation unit serves as the user interface and is responsible for data processing and output as well as control and monitoring functions. | ||||||||
|
|||||||||
Analog outputs | 3 outputs: 0/4 … 20 mA, 500 Ω Electrically isolated |
||||||||
Analog inputs | 1 input: 0 … 20 mA, 100 Ω |
||||||||
Digital outputs | 3 relay contacts: + 48 V AC, 1 A, 60 W / 48 V DC, 1 A, 30 W Preset for failure, maintenance and functional control |
||||||||
Digital inputs | 3 inputs: + 24 V |
||||||||
|
|||||||||
|
|||||||||
|
|||||||||
Input | Arrow keys
Functional keys |
||||||||
Operation | Menu-driven operation via LC-display and membrane keyboard | ||||||||
Model | Cast metal enclosure | ||||||||
|
|||||||||
|
|||||||||
|
Description | To lengthen the internal CAN-Bus connection with cable provided by the customer | ||||
|
|||||
|
Description | Fixture to flanges with connections for purge air and external cabelling | ||||
|
|||||
|
|||||
|
|||||
Integrated components | PT1000 temperature sensor
Pressure sensor |
Description | Fixture to flanges with connections for purge air and external cabelling | ||||
|
|||||
|
|||||
|
Description | Unit to provide dust-free air for flushing of optical surfaces | ||||||
|
|||||||
|
|||||||
|
|||||||
|
|||||||
|
|||||||
|
|||||||
|
|||||||
Test functions | Pressure switch (switching point –35 hPa) | ||||||
Integrated components | 2-step air filter, type Europiclon, dust capacity 200 g |
Reviews