Measured values |
CO2, SO2, NO, NO2, O2 |
Measurement principles |
NDIR spectroscopy, NDUV spectroscopy, electrochemical cell |
Sample quantity |
|
|
60 l/h … 100 l/h |
|
Measuring ranges |
|
CO2 |
0 … 25 Vol.-% |
SO2 |
0 … 100 ppm / 0 … 500 ppm |
NO |
0 … 300 ppm / 0 … 1,500 ppm |
NO2 |
0 … 200 ppm / 0 … 500 ppm |
O2 |
0 … 21 Vol.-% |
|
Response time (t90) |
|
|
15 s … 30 s
Including sample gas path and gas sampling probe |
|
Accuracy |
|
|
< 1 %
Of measuring range full scale |
|
Sensitivity drift |
|
|
< 2 %: of measuring range full scale per week |
|
Zero point drift |
|
|
< 2 %: of measuring range full scale per week |
|
Reference point drift |
|
|
< 2 %: of measuring range full scale per week |
|
|
Process temperature |
|
|
+10 °C … +550 °C |
|
Process pressure |
|
|
–90 hPa … 200 hPa
Relative |
|
|
Ambient temperature |
|
|
+5 °C … +45 °C |
|
Storage temperature |
|
|
–20 °C … +70 °C |
|
Ambient pressure |
|
|
900 hPa … 1,100 hPa |
|
Ambient humidity |
|
|
≤ 90 %
Non-condensing |
|
Conformities |
MARPOL Annex VI and NTC 2008 – MEPC.177(58)
Guidelines for exhaust gas cleaning systems – MEPC.184(59)
Guidelines for SCR reduction systems – MEPC.198(62)
DNV GL Rules for Type Approvals (2012) |
Electrical safety |
CE, DNV GL Rules |
|
Analog outputs |
8 outputs:
0 … 24 mA
Electrically isolated |
Analog inputs |
2 inputs:
0 … 20 mA |
Digital outputs |
16 outputs:
Changeover switch, 1-pin, 3 connections |
Digital inputs |
8 inputs:
+ 42 V |
Modbus |
✔ |
Type of fieldbus integration |
TCP |
|
Ethernet |
✔ |
Function |
Connection to OPC server |
|
Indication |
|
|
LC display |
|
Status LEDs: “Power”, “Maintenance request” and “Fault” |
|
Input |
Functional keys |
Operation |
Via LC display or SOPAS ET software, multiple operating levels, password-protected |
Model |
Steel sheet enclosure |
Dimensions (W x H x D) |
|
|
Sample conditioning
Distribution unit
Analyzer |
|
500 mm x 560 mm x 210 mm
600 mm x 660 mm x 210 mm
550 mm x 740 mm x 319 mm |
|
Weight |
|
Sample conditioning |
27 kg |
Distribution unit |
30 kg |
Analyzer |
37 kg |
|
Material in contact with media |
PTFE, Viton B, PVDF, stainless steel 1.4571, platinum, nickel, Aluminum, CaF2, Hastelloy |
Mounting |
Wall-mounting |
Power supply |
|
Voltage |
115 V / 230 V |
|
Different power supply via upstream transformer |
Frequency |
50 Hz / 60 Hz |
Current consumption |
At 230 V AC: ≤ 8 A |
Power consumption |
Analyzer: ≤ 300 W
Gas sampling probe: ≤ 400 W
Sample gas line, heated: ≤ 60 W/m
Sample conditioning: ≤ 150 W |
|
Auxiliaries |
|
Compressed air |
≤ 100 l/h
Instrument air: 0.5 … 1 bar, oil content max. 0.1 mg/m³ |
|
Sample gas connections |
|
|
Swagelok DN 4/6 |
|
Auxiliary gas connections |
|
Compressed air |
Hose connector DN 4/6 |
Test gas |
Hose connector DN 4/6 |
|
Corrective functions |
Automatic zero point adjustment with N2, weekly |
System components |
Sampling probe, heated, including filter unit
Sample gas line, partially heated
Sample conditioning
MARSIC200 distribution unit
Analyzer |
Integrated components |
Sample gas pump
Pressure sensor
Flow sensor |