The MCP-200 is a real-time concentration monitor for chemical species that absorb IR radiation.
From the MicroSpec series comes the MCP-200, a concentration monitor for species that absorb IR radiation. This solid state package combines a non-dispersive IR detector and a proprietary optical path design. Engineered to be compact and modular, the MCP-200 excels as both a rugged standalone and an integrated component.
The MicroSpec MCP-200 is used to measure the following chemicals:
| IN LIQUID PHASE |
|
| IN GAS PHASE | carbon monoxide | CO |
| carbon dioxide | CO2 | |
| ethylene | C2H4 | |
| methane equivalency | CH4 |
The MCP-200 uses a technology known as Non-Dispersive Infrared (NDIR) Photometry. In a ruggedized package, the MCP-200 pairs an NDIR photometer (2-10 micron) using a tungsten black body source with a proprietary-design optical flow cell. The path length of the flow cell is specialized per measurement application.
The MCP-200 uses serial communication between the detector and the HMI.
Note: All performance specifications are subject to the assumption that the sample conditioning system and unit installation are approved by Applied Analytics. For any other arrangement, please inquire directly with Sales.
| Measurement Principle | Non-dispersive IR photometry (2 to 10 micron) |
| Light Source | Tungsten black body source |
| Path Length | Application-dependent |
| Sample Introduction | Continuous flow from positive pressure stream |
| Sample Conditioning | Custom design per application |
| Analyzer Calibration | If possible, analyzer is factory calibrated with certified calibration fluids; no re-calibration required after initial calibration; measurement normalized by Auto Zero |
| Reading Verification | Simple verification with samples |
| Human Machine Interface | Industrial controller with touch-screen LCD display running ECLIPSE™ Software |
| Data Storage | Solid State Drive |
| OPERATING CONDITIONS | |
| Analyzer Environment | Indoor/Outdoor (no shelter required) |
| Ambient Temperature | Standard: 0 to 35 °C (32 to 95 °F) Optional: -20 to 55 °C (-4 to 131 °F) To avoid radiational heating, use of a sunshade is recommended for systems installed in direct sunlight. |
| Sample Temperature | Standard: -20 to 50 °C (-4 to 122 °F) Contact Applied Analytics for temperatures above 50 °C (122 °F) |
| Sample Pressure | 500 psi |
| UTILITIES | |
| Electrical | 5 VDC, 24 VDC controller |
| Power Consumption | 7 watts (maximum) |
| OUTPUTS | |
| Standard Outputs | 1x galvanically isolated 4-20mA analog output per measured analyte(up to 3; additional available by upgrade) 2x digital outputs for fault and SCS control |
| Optional Outputs | Modbus TCP/IP; RS-232; RS-485; Fieldbus; Profibus; HART; |
| PHYSICAL SPECIFICATIONS | |
| Dimensions | 3.75″H x (path length)W x 3.75″D |
| Path Length | 7″ to 17″ depending on application |
| Weight | 10-30 lbs depending on path length |
| Process Connections | 1/4” tube fittings |
| Wetted Materials | stainless steel 316L, K7 glass, Viton |