MASTER SERIES
SMART
OVERVIEW
Essential in investigation and quality control Laboratories.
SCREEN DATA
Selected speed – rpm
Selected spindle – SP
Viscosity reading – cP (mPa·s) or cSt
Percentatge of full scale – %
Sample temperature – ºC or ºF
Shear Rate (with coaxial spindles) – SR (s-1)
Shear Stress (with coaxial spindles) – SS (N/m2)
Density (introduced by the user) – g/cm3
VISCOSITY READING
Dynamic viscosity – cP or mPa·s
Kinematic viscosity – cSt
Units Converter from – SI to CGS
PROGRAM FEATURES
Time to torque: Ending of the test upon reaching a programmed torque
Time to stop: Ending of the test upon reaching a programmed time
10 working memories
OTHER MAIN FEATURES
- AUTO-TEST with visual and resonant alarm
- AUTO-RANGE function
- Temperature Reading through PT100 probe
- User-enabled viscosity and temperature calibration
- 6 language options
- Port: USB
- Datalogger: Posibility to tranfer data to a pendrive into Excel format
- 6 key Touch Keyboard
Spindles
AISI 316 Stainless steel spindle, easily to identify according to its letter and number, in terms of the range of viscosity. Our units fulfills the next standards: These are the standards our units follow: BS: 6075, 5350
- BS: 6075, 5350
- ISO:2555,1652
- ASTM: 115, 789, 1076, 1084, 1286, 1417, 1439, 1638, 1824, 2196, 2336, 2364, 2393, 2556, 2669, 2849, 2983, 2994, 3232, 3236, 3716
Standard delivery
- The equipement is supplied complete with standard spindles4 spindles for L model
6 spindles for R and H models
Viscometer stand - Spindle protector
- Temperature probe PT100
- Carring case
TECHNICAL SPECIFICATIONS
Precision: +/- 1% full scale of range
Resolution: For a minus viscosity of 100 cP : 0.01 cP For a major viscosity of 1000 cP : 0.1 cP For a major viscosity of 5000 cP : 1.0 cP For a major viscosity of 10.000 cP : 5.0 cP For a major viscosity of 25.000 cP : 10.0 cP For a major viscosity of 50.000 cP : 25.0 cP For a major viscosity of 100.000 cP : 100.0 cP For a major viscosity of 1.000.000 cP : 1.000.0 cP
Repeatability: 0.2%
Temperature probe features: Temperature limits: -40ºC to 300ºC -40ºF to 572ºF Resolution: 0.1ºC / -17.722 ºF Precision: +/- 0.2ºC / +/- 17.666 ºF Type of probe: PT100 supplied at 110-240VAC, 50/60 Hz.
Software: Fungilab Data Boss (optional): The Fungilab Data Boss software complies the FDA 21CFR PART 11 regulation
ACCESSORIES
APM
Small Sample Adapter with circulation jacket (without TL or TR spindles) Sample volume (6.7 – 13 ml.) Compatible with Brookfield viscometers
APM/B
Small Sample Adapter without circulation jacket (without TL or TR spindles) Sample volume (6.7 – 13 ml.) Compatible with Brookfield viscometers
LCP
Low Viscosity Adapter with circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield viscometers
LCP/B
Low Viscosity Adapter without circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield viscometers
HELDAL
Helix Drive Unit Accessory for measuring non-flowing substances viscosity (with spindles)
THERMOSPHERE
Temperature control unit up to 300 ºC
CODE | MODEL | MEASURING RANGE (CP) | SPEED (R.P.M) | NUMBER OF SPEEDS |
---|---|---|---|---|
V210003 | SMART L | *1 – 6.000.000 | 0.01 – 200 | 54 |
V210002 | SMART R | 25 – 40.000.000 | 0.01 – 200 | 54 |
V210001 | SMART H | 200 – 320.000.000 | 0.01 – 200 | 54 |
The viscosity range of the equipment is referenced between 0.01 and 100 rpm.
CODE | MODEL | MEASURING RANGE (CP) | SPEED (R.P.M) | NUMBER OF SPEEDS |
---|---|---|---|---|
V210003 | SMART L | *1 – 6.000.000 | 0.01 – 200 | 54 |
V210002 | SMART R | 25 – 40.000.000 | 0.01 – 200 | 54 |
V210001 | SMART H | 200 – 320.000.000 | 0.01 – 200 | 54 |
The viscosity range of the equipment is referenced between 0.01 and 100 rpm.
PPR
CODE | MODEL | MEASURING RANGE (CP) | SPEED (R.P.M) | NUMBER OF SPEEDS |
---|---|---|---|---|
V211003 | SMART L + PPR | *1 – 6.000.000 | 0.01 – 200 | 54 |
V211002 | SMART R + PPR | 25 – 40.000.000 | 0.01 – 200 | 54 |
V211001 | SMART H + PPR | 200 – 320.000.000 | 0.01 – 200 | 54 |
The viscosity range of the equipment is referenced between 0.01 and 100 rpm.
Ranges
- (L) Low viscosity model
- (M) Medium viscosity model
- (H) High viscosity model
Low viscosity:The minimum viscosity when using a “L” range with standard spindles is 10cP. (*) For measurements <10cP, its recommended to use in conjunction with the low viscosity adaptor (LCP or LCP/B)
Reviews
There are no reviews yet.